Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ArXiv ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38699168

RESUMO

The nuclear magnetic resonance signal from sodium (23Na) nuclei demonstrates a fast bi-exponential T2 decay in biological tissues (T2,short = 0.5-5 ms and T2,long = 10-30 ms). Hence, blurring observed in sodium images acquired with center-out sequences is generally assumed to be dominated by signal attenuation at higher k-space frequencies. Most of the studies in the field primarily focus on the impact of readout duration on blurring but neglect the impact of resolution. In this paper, we examine the blurring effect of short T2 on images at different resolutions. A series of simulations, as well as phantom and in vivo scans were performed at varying resolutions and readout durations in order to evaluate progressive changes in image quality. We demonstrate that, given a fixed readout duration, T2 decay produces distinct blurring effects at different resolutions. Therefore, in addition to voxel size-dependent partial volume effects, the choice of resolution adds additional T2-dependent blurring.

2.
bioRxiv ; 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38328173

RESUMO

Functional magnetic resonance imaging (fMRI) has emerged as an essential tool for exploring human brain function. Submillimeter fMRI, in particular, has emerged as a tool to study mesoscopic computations. The inherently low signal-to-noise ratio (SNR) at submillimeter resolutions warrants the use of denoising approaches tailored at reducing thermal noise - the dominant contributing noise component in high resolution fMRI. NORDIC PCA is one of such approaches, and has been benchmarked against other approaches in several applications. Here, we investigate the effects that two versions of NORDIC denoising have on auditory submillimeter data. As investigating auditory functional responses poses unique challenges, we anticipated that the benefit of this technique would be especially pronounced. Our results show that NORDIC denoising improves the detection sensitivity and the reliability of estimates in submillimeter auditory fMRI data. These effects can be explained by the reduction of the noise-induced signal variability. However, we also observed a reduction in the average response amplitude (percent signal), which may suggest that a small amount of signal was also removed. We conclude that, while evaluating the effects of the signal reduction induced by NORDIC may be necessary for each application, using NORDIC in high resolution auditory fMRI studies may be advantageous because of the large reduction in variability of the estimated responses.

3.
NMR Biomed ; 36(10): e4959, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37186038

RESUMO

In this work, we introduce a super-resolution method that generates a high-resolution (HR) sodium (23 Na) image from simultaneously acquired low-resolution (LR) 23 Na density-weighted MRI and HR proton density, T1 , and T2 maps from proton (1 H) MR fingerprinting in the brain at 7 T. The core of our method is a partial least squares regression between the HR (1 H) images and the LR (23 Na) image. An iterative loop and deconvolution with the point spread function of each acquired image were included in the algorithm to generate a final HR 23 Na image without losing features from the LR 23 Na image. The method was applied to simultaneously acquired HR proton and LR sodium data with in-plane resolution ratios between sodium and proton data of 3.8 and 1.9 and the same slice thickness. Four volunteers were scanned to evaluate the method's performance. For the data with a resolution ratio of 3.8, the mean absolute difference between the generated and ground truth HR 23 Na images was in the range of 1.5%-7.2% of the ground truth with a multiscale structural similarity index (M-SSIM) of 0.93 ± 0.03. For the data with a resolution ratio of 1.9, the mean absolute difference was in the range of 4.8%-6.3% with an M-SSIM of 0.95 ± 0.01.


Assuntos
Prótons , Sódio , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Algoritmos
4.
Sci Rep ; 12(1): 14156, 2022 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-35986071

RESUMO

Proton MRI can provide detailed morphological images, but it reveals little information about cell homeostasis. On the other hand, sodium MRI can provide metabolic information but cannot resolve fine structures. The complementary nature of proton and sodium MRI raises the prospect of their combined use in a single experiment. In this work, we assessed the repeatability of normalized proton density (PD), T1, T2, and normalized sodium density-weighted quantification measured with simultaneous 3D 1H MRF/23Na MRI in the brain at 7 T, from ten healthy volunteers who were scanned three times each. The coefficients of variation (CV) and the intra-class correlation (ICC) were calculated for the mean and standard deviation (SD) of these 4 parameters in grey matter, white matter, and cerebrospinal fluid. As result, the CVs were lower than 3.3% for the mean values and lower than 6.9% for the SD values. The ICCs were higher than 0.61 in all 24 measurements. We conclude that the measurements of normalized PD, T1, T2, and normalized sodium density-weighted from simultaneous 3D 1H MRF/23Na MRI in the brain at 7 T showed high repeatability. We estimate that changes > 6.6% (> 2 CVs) in mean values of both 1H and 23Na metrics could be detectable with this method.


Assuntos
Imageamento por Ressonância Magnética , Prótons , Encéfalo/metabolismo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sódio/metabolismo
5.
Magn Reson Med ; 87(5): 2299-2312, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34971454

RESUMO

PURPOSE: To develop a 3D MR technique to simultaneously acquire proton multiparametric maps (T1 , T2 , and proton density) and sodium density weighted images over the whole brain. METHODS: We implemented a 3D stack-of-stars MR pulse sequence which consists of interleaved proton (1 H) and sodium (23 Na) excitations, tailored slice encoding gradients that can encode the same slice for both nuclei, and simultaneous readout with different radial trajectories (1 H, full-radial; 23 Na, center-out radial). The receive chain of our 7T scanner was modified to enable simultaneous acquisition of 1 H and 23 Na signal. A heuristically optimized flip angle train was implemented for proton MR fingerprinting (MRF). The SNR and the accuracy of proton T1 and T2 were evaluated in phantoms. Finally, in vivo application of the method was demonstrated in five healthy subjects. RESULTS: The SNR for the simultaneous measurement was almost identical to that for the single-nucleus measurements (<2% change). The proton T1 and T2 maps remained similar to the results from a reference 2D MRF technique (normalized RMS error in T1 ≈ 4.2% and T2 ≈ 11.3%). Measurements in healthy subjects corroborated these results and demonstrated the feasibility of our method for in vivo application. The in vivo T1 values measured using our method were lower than the results measured by other conventional techniques. CONCLUSIONS: With the 3D simultaneous implementation, we were able to acquire sodium and proton density weighted images in addition to proton T1 , T2 , and B1+ from 1 H MRF that covers the whole brain volume within 21 min.


Assuntos
Processamento de Imagem Assistida por Computador , Prótons , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Sódio
6.
NMR Biomed ; 34(12): e4608, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34476861

RESUMO

The objective of the current study was to design and build a dual-tuned coil array for simultaneous 23 Na/1 H MRI of the human brain at 7 T. Quality factor, experimental B1+ measurements, and electromagnetic simulations in prototypes showed that setups consisting of geometrically interleaved 1 H and 23 Na loops performed better than or similar to 1 H or 23 Na loops in isolation. Based on these preliminary findings, we built a transmit/receive eight-channel 23 Na loop array that was geometrically interleaved with a transmit/receive eight-channel 1 H loop array. We assessed the performance of the manufactured array with mononuclear signal-to-noise ratio (SNR) and B1+ measurements, along with multinuclear magnetic resonance fingerprinting maps and images. The 23 Na array within the developed dual-tuned device provided more than 50% gain in peripheral SNR and similar B1+ uniformity and coverage as a reference birdcage coil of similar size. The 1 H array provided good B1+ uniformity in the brain, excluding the cerebellum and brain stem. The integrated 23 Na and 1 H arrays were used to demonstrate truly simultaneous quantitative 1 H mapping and 23 Na imaging.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Prótons , Razão Sinal-Ruído , Sódio
7.
NMR Biomed ; 34(7): e4531, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33902155

RESUMO

In this work, we propose a free-breathing magnetic resonance fingerprinting (MRF) method that can be used to obtain B1+ -robust quantitative T1 maps of the abdomen in a clinically acceptable time. A three-dimensional MRF sequence with a radial stack-of-stars trajectory was implemented, and its k-space acquisition ordering was adjusted to improve motion-robustness in the context of MRF. The flip angle pattern was optimized using the Cramér-Rao Lower Bound, and the encoding efficiency of sequences with 300, 600, 900 and 1800 flip angles was evaluated. To validate the sequence, a movable multicompartment phantom was developed. Reference multiparametric maps were acquired under stationary conditions using a previously validated MRF method. Periodic motion of the phantom was used to investigate the motion-robustness of the proposed sequence. The best performing sequence length (600 flip angles) was used to image the abdomen during a free-breathing volunteer scan. When using a series of 600 or more flip angles, the estimated T1 values in the stationary phantom showed good agreement with the reference scan. Phantom experiments revealed that motion-related artifacts can appear in the quantitative maps and confirmed that a motion-robust k-space ordering is essential. The in vivo scan demonstrated that the proposed sequence can produce clean parameter maps while the subject breathes freely. Using this sequence, it is possible to generate B1+ -robust quantitative maps of T1 and B1+ next to M0 -weighted images under free-breathing conditions at a clinically usable resolution within 5 min.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração , Humanos , Movimento (Física) , Imagens de Fantasmas
8.
Int J Clin Pharmacol Ther ; 58(7): 375-386, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32301702

RESUMO

OBJECTIVE: This study evaluated different influences of 14 single nucleotide polymorphisms (SNPs) and demographic factors leading to individual differences in the antihypertensive efficacy of felodipine in healthy Chinese subjects. MATERIALS AND METHODS: 24 subjects were sequenced for candidate SNPs. Plasma samples were obtained as clinical trial protocol, and were determined by a HPLC-MS/MS method. Pharmacokinetic parameters were calculated by WinNonlin 6.0. Statistical analysis was mainly performed by SPSS 22.0. A multiple linear regression model provided different weight coefficients of different demographic and genetic factors. RESULTS: The trend of Cmax is almost consistent with AUCss increase, but tmax of individuals is different; the antihypertensive effect of felodipine is individually different. A significant association was observed between systolic blood pressure decrease (ΔSBP) and SNPs of CACNA1C, CACNA1D, GNB3 respectively, while CACNA1C and CACNA1 were associated with diastolic blood pressure decrease (ΔDBP). CYP3A5 rs766746 and CYP3A4 rs2242480 were linked with Cmax and AUCss, and ABCB1 rs1045642 was associated with T1/2. Significant relationships were shown between AUCss and ΔSBP (p = 0.022) as well as Cmax and ΔSBP (p = 0.015). CONCLUSION: The efficacy of felodipine is individually different, influenced especially by CACNA1C rs1051375 and ABCB1 rs1045642. ΔDBP is associated with ΔSBP in multiple-dosing of felodipine in healthy Chinese subjects.


Assuntos
Anti-Hipertensivos , Felodipino , Polimorfismo de Nucleotídeo Único , Subfamília B de Transportador de Cassetes de Ligação de ATP/genética , Anti-Hipertensivos/farmacologia , Povo Asiático/genética , Canais de Cálcio Tipo L/genética , Citocromo P-450 CYP3A , Felodipino/farmacologia , Humanos , Espectrometria de Massas em Tandem
9.
Magn Reson Med ; 84(1): 128-141, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31762101

RESUMO

PURPOSE: To study the effects of magnetization transfer (MT, in which a semi-solid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF). METHODS: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off-resonance MT pulses and a dictionary with an MT dimension, generated by incorporating a two-pool model, were used to estimate the fractional pool size in addition to the B1+ , T1 , and T2 values. The proposed method was evaluated in the human brain. RESULTS: Simulations and phantom experiments showed that an MRF signal obtained from a cross-linked bovine serum sample is influenced by MT. Using a dictionary based on an MT model, a better match between simulations and acquired MR signals can be obtained (NRMSE 1.3% vs. 4.7%). Adding off-resonance MT pulses can improve the differentiation of MT from T1 and T2 . In vivo results showed that MT affects the MRF signals from white matter (fractional pool-size ~16%) and gray matter (fractional pool-size ~10%). Furthermore, longer T1 (~1060 ms vs. ~860 ms) and T2 values (~47 ms vs. ~35 ms) can be observed in white matter if MT is accounted for. CONCLUSION: Our experiments demonstrated a potential influence of MT on the quantification of T1 and T2 with MRF. A model that encompasses MT effects can improve the accuracy of estimated relaxation parameters and allows quantification of the fractional pool size.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Animais , Encéfalo/diagnóstico por imagem , Bovinos , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
Magn Reson Med ; 83(6): 2232-2242, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31746048

RESUMO

PURPOSE: The goal of this work is to demonstrate a method for the simultaneous acquisition of proton multiparametric maps (T1 , T2 , and proton density) and sodium density images in 1 single scan. We hope that the development of such capabilities will help to ease the implementation of sodium MRI in clinical trials and provide more opportunities for researchers to investigate metabolism through sodium MRI. METHODS: We developed a sequence based on magnetic resonance fingerprinting (MRF), which contains interleaved proton (1 H) and sodium (23 Na) excitations followed by a simultaneous center-out radial readout for both nuclei. The receive chain of a 7T scanner was modified to enable simultaneous acquisition of 1 H and 23 Na signal. The obtained signal-to-noise ratio (SNR) was evaluated, and the accuracy of both proton T1 , T2 , and B1+ and sodium density maps were verified in phantoms. Finally, the method was demonstrated in 2 healthy subjects. RESULTS: The SNR obtained using the simultaneous measurement was almost identical to single-nucleus measurements (<1% change). Similarly, the proton T1 and T2 maps remained stable (normalized root mean square error in T1 ≈ 2.2%, in T2 ≈ 1.4%, and B1+ ≈ 5.4%), which indicates that the proposed sequence and hardware have no significant effects on the signal from either nucleus. In vivo measurements corroborated these results and demonstrated the feasibility of our method for in vivo application. CONCLUSIONS: With the proposed approach, we were able to simultaneously acquire sodium density images in addition to proton T1 , T2 , and B1+ maps as well as proton density images.


Assuntos
Prótons , Sódio , Encéfalo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
11.
Magn Reson Imaging ; 54: 241-248, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30193953

RESUMO

PURPOSE: To explore the motion sensitivity of magnetic resonance fingerprinting (MRF), we performed experiments with different types of motion at various time intervals during multiple scans. Additionally, we investigated the possibility to correct the motion artifacts based on redundancy in MRF data. METHODS: A radial version of the FISP-MRF sequence was used to acquire one transverse slice through the brain. Three subjects were instructed to move in different patterns (in-plane rotation, through-plane wiggle, complex movements, adjust head position, and pretend itch) during different time intervals. The potential to correct motion artifacts in MRF by removing motion-corrupted data points from the fingerprints and dictionary was evaluated. RESULTS: Morphological structures were well preserved in multi-parametric maps despite subject motion. Although the bulk T1 values were not significantly affected by motion, fine structures were blurred when in-plane motion was present during the first part of the scan. On the other hand, T2 values showed a considerable deviation from the motion-free results, especially when through-plane motion was present in the middle of the scan (-44% on average). Explicitly removing the motion-corrupted data from the scan partially restored the T2 values (-10% on average). CONCLUSION: Our experimental results showed that different kinds of motion have distinct effects on the precision and effective resolution of the parametric maps measured with MRF. Although MRF-based acquisitions can be relatively robust to motion effects occurring at the beginning or end of the sequence, relying on redundancy in the data alone is not sufficient to assure the accuracy of the multi-parametric maps in all cases.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Movimento (Física) , Algoritmos , Artefatos , Mapeamento Encefálico/métodos , Voluntários Saudáveis , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
12.
Magn Reson Med ; 78(1): 383-386, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27714839

RESUMO

PURPOSE: To illustrate the potential for high permittivity materials to be used in decreasing peak local SAR associated with implants when the imaging region is far from the implant. METHODS: We performed numerical simulations of a human subject with a pacemaker in a body-sized birdcage coil driven at 128 MHz with and without a thin (5 mm) shell of material of high electric permittivity around the head. RESULTS: For a shell with relative permittivity of 600, the maximum specific energy absorption rate averaged over any 1 g of tissue near the pacemaker was reduced by 73.5% for a given B1 field strength at the center of the brain. CONCLUSION: Although further study is required, initial simulations indicate that strategic use of high permittivity materials may broaden the conditions under which patients with certain implants can be imaged safely. Magn Reson Med 78:383-386, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Materiais Biocompatíveis/química , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Marca-Passo Artificial , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Imagem Corporal Total/instrumentação , Absorção de Radiação , Impedância Elétrica , Eletrodos Implantados , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Campos Magnéticos , Teste de Materiais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
13.
J Ethnopharmacol ; 179: 9-15, 2016 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-26719283

RESUMO

ETHNOPHARMACOLOGY RELEVANCE: Albiflorin, a monoterpene glycoside, is a main component of Radix paeoniae Alba, which could be a Chinese herbal medicine used in the treatment of psychiatric disorders. However, the exact role of albiflorin in depression is poorly understood. AIM OF THE STUDY: The current study aimed to evaluate the antidepressant effect of albiflorin in mice and rats, and the possible mechanism was also determined. MATERIALS AND METHODS: The antidepressant-like effects of albiflorin was determined by using animal models of depression including forced swim and tail suspension tests in mice and chronic unpredictable stress (CUS) in rats. The acting mechanism was explored by determining the effect of albiflorin on the expression of brain-derived neurotrophic factor (BDNF) in the hippocampus by western blot and the levels of monoamine in the hippocampus by HPLC. RESULTS: Our results showed that 7 days treatment with albiflorin significantly decreased immobility time in the forced swimming test (FST) and the tail suspension test (TST) at doses of 3.5, 7.0 and 14.0mg/kg without alter the locomotor activity in mice. Moreover, western blot analysis showed that albiflorin could increase the expression of BDNF in the hippocampus. We further exposed rats to a chronic unpredictable stress (CUS) protocol for a period of 35d to induce depressive-like behaviors. We found that chronic treatment with albiflorin, at doses of 7.0 and 14.0mg (i.g., once daily for 35d), restored the sucrose preference in CUS rats. In the open-field test, albiflorin significantly increased the number of crossings and rearings in the CUS rats at three doses. Moreover, chronic treatment with albiflorin up-regulated the hippocampal BDNF expression levels and the hippocampal 5-HT, 5-HIAA, and NA levels. CONCLUSION: Albiflorin produced significant antidepressant-like effects, which were closely related to the hippocampal 5-HT/NE increase and BDNF expression. Our data indicated that albiflorin could be a potential anti-depressant drug.


Assuntos
Antidepressivos/uso terapêutico , Hidrocarbonetos Aromáticos com Pontes/uso terapêutico , Paeonia/química , Extratos Vegetais/uso terapêutico , Animais , Antidepressivos/química , Monoaminas Biogênicas/metabolismo , Fator Neurotrófico Derivado do Encéfalo/biossíntese , Hidrocarbonetos Aromáticos com Pontes/química , Preferências Alimentares , Elevação dos Membros Posteriores/psicologia , Hipocampo/efeitos dos fármacos , Hipocampo/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos ICR , Atividade Motora/efeitos dos fármacos , Extratos Vegetais/química , Ratos , Ratos Wistar , Estresse Psicológico/psicologia , Natação/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...